Three Electrode Potentiostat Galvanostat Model CS350

Techniques: Cyclic Voltammetry, Tafel, Eis, Lsv, Gcd, etc
Eis Freqency Range: 10μHz~1MHz
Current Range: ±2A
Voltage Range: ±10V
Applications: Battery, Corrosion, Sensor, Electrodeposition etc
Transport Package: Standard Carton
Gold Member Since 2019

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
CS350
Specification
36.5 x 30.5 x16 cm
Trademark
Corrtest
Origin
China
HS Code
9027809900
Production Capacity
1000 Sets/Year

Product Description

Three electrode potentiostat galvanostat
Corrtest Potentiostat Galvanostat is suitable for 2, 3, 4 or 5 electrode system. It contains a fast digital function generator, high-speed data acquisition circuitry, a potentiostat and a galvanostat. With high performance in stability and accuracy with advanced hardware and well-functioned software, it is a comprehensive research platform for corrosion, batteries, electrochemical analysis, sensor, life science and environmental chemistry etc.It will service your experiment with excellent performance.
Three Electrode Potentiostat Galvanostat Model CS350


HARDWARE FEATURES
Dual-channel high-speed 16bit/high-accuracy 24bit AD converter;
Built-in frequency response analyzer(FRA), frequency range: 10μHz~1MHz;
High-bandwidth high input impedance amplifier unit
Built-in FPGA DDS digital signals synthesizer
High-power Potentiostat/Galvanostat/ZRA;
Potential control range: ±10V; Compliance voltage: ±21V;
Current control range: ±2A ;
Potential resolution: 10μV; current resolution 1pA.


SOFTWARE FEATURES
1. CS studio software provides users a versatile smoothing/differential/ integration kit, which can complete the calculation of peak height, peak area and peak potential of CV curves. In CV technique and constant current charge and discharge, after measurement, during the data analysis, there is function of selecting the exact cycle(s) to show

Three Electrode Potentiostat Galvanostat Model CS350

2. CS studio also provides powerful non-linear fitting on Butler-Volmer equation of polarization curve. It can calculate Tafel slope, corrosion current density, limitation current, polarization resistance, corrosion rate. It can also calculate the power spectrum density, noise resistance and noise spectrum resistance based on the electrochemical noise measurements.
Three Electrode Potentiostat Galvanostat Model CS350

3. CS Studio software can achieve real time saving of the measuring data. The data can be automatically saved even in case of sudden power off.
4. CS studio kit has a built-in versatile timing policy for combination tests, which can facilitate the automation of experiments and save time.
5. CS studio software can achieve timing measurements. After setting the experiment and time, click start, then the experiment will be conducted automatically when it is the time.
6. Battery analysis: charge & discharge efficiency, capacity, specific capacitance, charge & discharge energy etc.
 
Three Electrode Potentiostat Galvanostat Model CS350

7. EIS analysis: Bode, Nyquist, Mott-Schottky plot
Three Electrode Potentiostat Galvanostat Model CS350
8. Data open in notepad( txt format) and Origin
9. 3D display
Three Electrode Potentiostat Galvanostat Model CS350

TECHNICAL ADVANTAGES
1. Impedance (EIS)
Corrtest Potentiostat Galvanostat applies correlation integral algorithm and dual-channel over-sampling technique, and has strong anti-interference ability. It is suitable for EIS measurements of high-impedance system (>109Ω, such as coating, concrete etc.). It can also be used to obtain Mott-Schottky curve and differential capacitance curve. During test, the software can display real-time open circuit potential(OCP) without entering.
2. Polarization curve
It can complete linear polarization curve and Tafel plot measurements. The user can set the anodic reversal current (passivation film breakdown current) of the cyclic polarization curve to determine material's pitting potential and protection potential and evaluate the its susceptibility to intergranular corrosion. The software employs non-linear fitting to analyze polarization curve, and can make fast evaluation of material's anti-corrosion ability and inhibitors.
3. Voltammetry
It can do the following electroanalysis methods: Linear Sweep Voltammetry(LSV), Cyclic Voltammetry(CV), Staircase Cyclic Voltammetry(SCV), Square wave voltammetry(SWV), Differential Pulse Voltammetry(DPV), Normal Pulse Voltammetry(NPV), AC voltammetry(ACV), Stripping voltammetry etc. It integrates calculation of peak area, peak current and standard curve analysis.
4. Electrochemical Noise
With high-resistance follower and zero-resistance ammeter, it measures the natural potential/current fluctuations in corrosion system. It can be used to study pitting corrosion, galvanic corrosion, crevice corrosion, and stress corrosion cracking etc. Through noise spectrum, we can evaluate the inducement, growth and death of metastable pitting and crack. Based on calculation of noise resistance and pitting index, it can complete localized corrosion monitoring.
5. Full floating measurement
Corrtest Potentiostat Galvanostat uses full-floating working electrode. It can be used for autoclave electrochemical measurements, on-line corrosion monitoring of metallic components under the ground (rebar in concrete, etc.)
6. User-defined methods
Corrtest Potentiostat Galvanostat supports user-defined combination measurements. The user can set cyclic  timing measurements of an electrochemical method or several methods.
  We are able to provide API functions and development examples, which facilitates some users' requirements for secondary development and self-defined measurements.

Specifications
Specifications 
Support 2-, 3- or 4-electrode system
Potential control range:  ±10V   Current control range: ±2A
Potential control accuracy: 0.1%×full range±1mV Current control accuracy: 0.1%×full range
Potential resolution: 10μV (>100Hz),3μV (<10Hz) Current sensitivity:1pA
Rise time: <1μS (<10mA), <10μS (<2A) Reference electrode input impedance:1012Ω||20pF
Current range: 2nA~2A, 10 ranges Compliance voltage: ±21V
Maximum current output: 2A CV and LSV scan rate : 0.001mV~10,000V/s
CA and CC pulse width: 0.0001~65,000s Current increment during scan: 1mA@1A/ms
Potential increment during scan: 0.076mV@1V/ms SWV frequency: 0.001~100 kHz
DPV and NPV pulse width: 0.0001~1000s AD data acquisition:16bit@1 MHz,20bit@1 kHz
DA Resolution:16bit, setup time:1μs Minimum potential increment in CV: 0.075mV
IMP frequency: 10μHz~1MHz Low-pass filters: Covering 8-decade
Potential and current range: Automatic
PC and O/S requirement
 Interface: USB 2.0 Operating System: Windows 2000/NT/XP/ win7/win8/win10
Weight / Measurements
Net weight: 6.5kg Gross weight: 10kg
Instrument size: 36.5 x 30.5 x16cm; After package: 52.5 x 37.5x 22.5cm
Electrochemical Impedance Spectroscopy(EIS)
Signal generator
Frequency range:10μHz~1MHz AC amplitude:1mV~2500mV
DC Bias:-10~+10V Output impedance:50Ω
Waveform: sine wave, triangular wave and square wave Wave distortion:<1%
Scanning mode: logarithmic/linear, increase/decrease
Signal analyzer
Integral time:minimum:10ms or the longest time of a cycle Maximum:106 cycles or 105s
Measurement delay:0~105s
DC offset compensation
Potential automatic compensation range:-10V~+10V Current compensation range:-1A~+1A
Bandwidth: 8-decade frequency range, automatic and manual setting

Software
Techniques included in CS350
Stable polarization: Open Circuit Potential (OCP), Potentiostatic (I-T measurement), Galvanostatic, Potentiodynamic (Tafel plot), Galvanodynamic
Transient polarization: Multi-Potential Steps, Multi-Current Steps, Potential Stair-Step (VSTEP), Galvanic Stair-Step (ISTEP)
Chrono Methods: Chronopotentiometry (CP), Chronoamperometry (CA), Chronocoulometry (CC)
Voltammetry: Cyclic Voltammetry (CV), Linear Sweep Voltammetry (LSV), Staircase Voltammetry (SCV), Differential Pulse Voltammetry (DPV), Normal Pulse Voltammetry (NPV), Square wave voltammetry (SWV), ACvoltammetry (ACV), Differential Normal Pulse Voltammetry (DNPV), 2nd Harmonic A. C. Voltammetry (SHACV), Fourier Transform AC Voltammetry(FTACV)
Stripping Voltammetry: Potentiostatic stripping, Linear stripping, Staircase stripping, Square wave stripping, Differential Pulse Voltammetry Stripping, Normal Pulse Voltammetry Stripping, Differential Normal Pulse Voltammetry Stripping.
Amprometric: Differential Pulse Amperometry(DPA), Double Differential PulseAmperometry(DDPA),Triple Pulse Amperometry (TPA), Integrated Pulse Amperometric Detection (IPAD)
Impedance: EIS vs Frequency (IMP), EIS vs Time (IMPT), EIS vs Potential (IMPE)
Corrosion testing: Electrochemical Noise (EN), Zero Resistance Ammeter (ZRA), Electrochemical Potentiokinetic Reactivation(EPR)
Battery testing: Battery charge and discharge, Galvanostatic charge and discharge
Extensions: Data Logger, Electrochemical stripping/deposition, Bulk electrolysis with Coulometry

How to understand three electrode system and two electrode system
The three electrode system is composed of working electrode (WE), reference electrode (RE) and counter electrode (CE). WE and CE constitute polarization circuit. WE and RE constitute measurement  circuit. There is no current flow on RE. Current flows from the WE to CE. No current flows through RE.
Working electrode(WE) is the Object of the research.
Pay attention that the surface of the WE should be clean. That's very important during electrochemical measurements. Once the surface is contaminated with impurities, there will be interference current.
Reference Electrode (RE): an electrode with a constant electrochemical potential. Not change with current and experiment conditions
Counter Electrode (CE): a current-carrying electrode that completes the cell circuit. It doesn't affect the experiment results, no matter the shape, material, and reactions.
Two-electrode system there is no individual RE involved in the experiment in two-electrode system. When using the Corrtest potentiostat galvanostat for two-electrode system testing, the CE can be used as RE to provide reference potential. During measurements, you need to connect the RE&CE clamps to one common electrode.



 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2019

Suppliers with verified business licenses

Manufacturer/Factory
Registered Capital
739010.91 USD
Plant Area
681.69 square meters