Double-Channel Potentiostat Galvanostat Bipotentiostat Electrochemical Workstation CS2150m

Product Details
After-sales Service: Free
Warranty: 3 Years
Customized: Customized
Gold Member Since 2019

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
739010.91 USD
Plant Area
681.69 square meters
  • Double-Channel Potentiostat Galvanostat Bipotentiostat Electrochemical Workstation CS2150m
  • Double-Channel Potentiostat Galvanostat Bipotentiostat Electrochemical Workstation CS2150m
Find Similar Products

Basic Info.

Model NO.
CS2150M
Structure
Desktop
Certification
CE, ISO
Application
School, Hospital, Lab
Type
Measurement Type
Number of Channels
2
Eis
No
Max. Current Output
±1A on Each Channel
Potential Range
±10V
Eis Frequency
10μHz~1MHz
Applications
Rrde, Battery, Materials, Corrosion etc
Power Supply
AC 90V~240V, 50/60Hz
Weight
7kg
Transport Package
Carton
Specification
36x30x16CM
Trademark
Corrtest
Origin
China
HS Code
9027899090
Production Capacity
1000 Sets/Year

Product Description

    BiPotentiostat/BiGalvanostat model CS2150M(without EIS) has two sets of built-in independent potentiostat /galvanostat. So it equals that you have 2 sets single-potentiostat in one chassis. Full floating module and electrical isolation design guarantee each channel is totally independent, which ensures accurate data. Experiments can be conducted simultaneously in each channel. Besides this, the two channels can jointly complete experiment of two-working electrode system such as RRDE and Hydrogen diffusion. CS2150M bipotentiostat is the real double-channel potentiostat. It uses Ethernet connection. Neither of the channels includes EIS function.Double-Channel Potentiostat Galvanostat Bipotentiostat Electrochemical Workstation CS2150m
Applications
(1) Electrosythesis, electrodeposition (electroplating), anodic oxidation, electrolysis
(2) Oxygen reduction reaction(ORR), oxygen evolution reaction (OER), Hydrogen evolution reaction(HER), carbon dioxide reduction.
(3) Energy and materials (Li-ion battery, solar cell, fuel cell, supercapacitor), advanced function materials, and sensor.
(4) Corrosion behavior of metals, and anti-corrosion evaluation

(5) Fast evaluation of inhibitor, water quality stabilizer, coating, and cathodic protection efficiency.




Typical applications for the bipotentiostat

Rotating Ring-Disk Electrode (RRDE)
Oxidation/reduction reaction (ORR) study: while measuring the polarization curve of disk electrode in the main channel, apply a constant polarization potential on the ring electrode, and thus detect the intermediate products on the disk electrode. RRDE test becomes the typical method for ORR study. CS2150M can be connected to any RRDE equipment.
Double-Channel Potentiostat Galvanostat Bipotentiostat Electrochemical Workstation CS2150m
Hydrogen Diffusion Test (HDT)

CS2150M bipotentiostat is combined with H-cells. By measuring current of cathode hydrogen charging and hydrogen atoms anode oxidation, it can further calculate the diffusion coefficient of hydrogen atoms in metal and hydrogen flux.

Double-Channel Potentiostat Galvanostat Bipotentiostat Electrochemical Workstation CS2150mSpecifications 
 
Specifications
Support 2-, 3- or 4-electrode system Interface: Ethernet
Potential control range:  ±10V on each channel Current control range: ±1A on each channel
Potential control accuracy: 0.1%×full range±1mV Current control accuracy: 0.1%×full range
Potential resolution: 10μV (>100Hz), 3μV (<10Hz) Current sensitivity:1pA
Rise time: <1μS (<10mA), <10μS (<2A) Reference electrode input impedance:1012Ω||20pF
Current range: 2nA~2A, 10 ranges Compliance voltage: ±21V
Maximum current output: ±2A CV and LSV scan rate: 0.001mV~10,000V/s
CA and CC pulse width: 0.0001~65,000s Current increment during scan: 1mA@1A/ms
Potential increment during scan: 0.076mV@1V/ms SWV frequency: 0.001~100 kHz
DPV and NPV pulse width: 0.0001~1000s AD data acquisition:16bit@1 MHz,20bit@1 kHz
DA Resolution:16bit, setup time:1μs Minimum potential increment in CV: 0.075mV
IMP frequency: 10μHz~1MHz Low-pass filters: Covering 8-decade
Potential and current range: Automatic Weight / Measurements: 7kg,36.5 x 30.5 x16cm
 Operating System: Windows 0/11

Techniques/Methods of CS2150M

Stable polarization
  • Open Circuit Potential (OCP)
  • Potentiostatic (I-T curve)
  • Galvanostatic
  • Potentiodynamic (Tafel plot)
  • Galvanodynamic (DGP)
  • Sweep-Step Functions (SSF)
Transient Polarization
  • Multi Potential Steps
  • Multi Current Steps
  • Potential Stair-Step (VSTEP)
  • Galvanic Stair-Step (ISTEP)
Chrono Method
  • Chronopotentiometry (CP)
  • Chronoamperametry (CA)
  • Chronocaulometry (CC)
Voltammetry
  • Linear Sweep Voltammetry (LSV)
  • Cylic Voltammetry (CV)
  • Staircase Voltammetry (SCV)
  • Square Wave Voltammetry (SWV)#
  • Differential Pulse Voltammetry (DPV)#
  • Normal Pulse Voltammetry (NPV)#
  • Differential Normal Pulse Voltammetry (DNPV)#
  • AC Voltammetry (ACV)
  • 2nd harmonic AC Voltammetry (SHACV)
  • Fourier Transform AC Voltammetry (FTACV)
#there is the corresponding stripping method. 
Amperometric
  • Differential Pulse Amperometry (DPA)
  • Double Differential Pulse Amperometry (DDPA)
  • Triple Pulse Amperometry (TPA)
  • Integrated Pulse Amperometric Detection (IPAD)
Corrosion Measurements
  • Cyclic polarization curve (CPP)
  • Linear polarization curve (LPR)
  • Electrochemical Potentiokinetic Reactivation (EPR)
  • Electrochemical Noise (EN)
  • Zero resistance Ammeter (ZRA)
Battery testing
  • Battery Charge and Discharge
  • Galvanostatic Charge and Discharge (GCD)
  • Potentiostatic Charging and Discharging
  • Potentiostatic Intermittent Titration Technique
  • Galvanostatic Intermittent Titration Technique
Extensions
  • Data Logger
  • Electrochemical Stripping/ Deposition
  • Bulk Eletrolysis with Coulometry (BE)
  • Rs Measurement
Software Features
Cyclic voltammetry: CS studio software provides users a versatile smoothing/differential/ integration kit, which can complete the calculation of peak height, peak area and peak potential of CV curves. In CV technique, during the data analysis, there is function of selecting exact cycle(s) to show. You can choose to see a cycle or some cycles as you want. You can also export data or vector graph of an exact cycle or several cycles.
Double-Channel Potentiostat Galvanostat Bipotentiostat Electrochemical Workstation CS2150m
Tafel plot and corrosion rate:
CS studio also provides powerful non-linear fitting on Butler-Volmer equation of polarization curve. It can calculate Tafel slope, corrosion current density, limitation current, polarization resistance, corrosion rate. It can also calculate the power spectrum density, noise resistance and noise spectrum resistance based on the electrochemical noise measurements.

Double-Channel Potentiostat Galvanostat Bipotentiostat Electrochemical Workstation CS2150m
Battery Test and analysis:
charge & discharge efficiency, capacity, specific capacitance, charge & discharge energy.

Double-Channel Potentiostat Galvanostat Bipotentiostat Electrochemical Workstation CS2150m
Real-time saving of data: The data can be automatically saved even in case of sudden power failure.
Combination/sequence test: it can achieve automation of experiments and save time. With the unique function of combination test, you can choose several experiments you want to run. Then you can make auto run of the pre-set experiments as you want without having to wait in the lab. This function is especially useful if you have multi experiments to run and save your time greatly.


Double-Channel Potentiostat Galvanostat Bipotentiostat Electrochemical Workstation CS2150m
Sequence Test: corrosion tests
 
Double-Channel Potentiostat Galvanostat Bipotentiostat Electrochemical Workstation CS2150m
SequenceTest: Pseudocapacitor tests

Data open: You can open the data files by txt format in notepad. Data can also be opened in Origin

BiPotentiostat / BiGalvanostat model CS2150M
Standard supply Include:
Instrument CS2150M x1
CS studio software x1
Power cable x1,
LAN  cable x1,
Cell cable x 4
Dummy cell (1kΩ||100µF) x2

After-sales Service (**All the after service is FREE)
1. Warranty period: 3 years.
2. Provide installation guide, manual, software installation video, and training videos.
3. Lifetime free software upgrading of the same model and technical service.
4. Free repair service


 
 







 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier