CS350 Eis Electrochemical Workstation

Product Details
Type: Electrochemical Workstation for Battery Test
Test Region: Charge and Discharge
Application: Lithium-ion Battery
Gold Member Since 2019

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
739010.91 USD
Plant Area
681.69 square meters
  • CS350 Eis Electrochemical Workstation
  • CS350 Eis Electrochemical Workstation
  • CS350 Eis Electrochemical Workstation
  • CS350 Eis Electrochemical Workstation
  • CS350 Eis Electrochemical Workstation
  • CS350 Eis Electrochemical Workstation
Find Similar Products

Basic Info.

Model NO.
CS350
Customized
Non-Customized
Eis Freqency Range
10μHz~1MHz
Current Range
±2A
Voltage Range
±10V
Applications
Li-ion Battery, Solar Cell, Fuel Cell
Transport Package
Standard Carton
Specification
36.5 x 30.5 x16 cm
Trademark
Corrtest
Origin
China
HS Code
9027809900
Production Capacity
1000 Sets/Year

Product Description

CS350 electrochemical workstation (potentiostat / galvanostat) contains a fast digital function generator, high-speed data acquisition circuitry, a potentiostat and a galvanostat. With high performance in stability and accuracy with advanced hardware and well-functioned software, it is a comprehensive research platform for corrosion, batteries, electrochemical analysis, sensor, life science and environmental chemistry etc.
CS350 Eis Electrochemical Workstation

Applications                  
(1) Reaction mechanism of Electrosynthesis, electrodeposition (electroplating), anodic oxidation, etc.
(2) Electrochemical analysis and sensor; 
(3) New energy materials (Li-ion battery, solar cell, fuel cell, supercapacitors), advanced functional materials, photoelectronic materials;
(4)Corrosion study of metals in water, concrete and soil etc;
(5) Fast evaluation of corrosion inhibitor, water stabilizer, coating and cathodic protection efficiency.


HARDWARE FEATURES
Dual-channel high-speed 16bit/high-accuracy 24bit AD converter;
Built-in frequency response analyzer(FRA), frequency range: 10μHz~1MHz;
High-bandwidth high input impedance amplifier unit
Built-in FPGA DDS digital signals synthesizer
High-power Potentiostat/Galvanostat/ZRA;
Potential control range: ±10V; Compliance voltage: ±21V;
Current control range: ±2A ;
Potential resolution: 10μV; current resolution 1pA.


SOFTWARE FEATURES
CS studio software provides users a versatile smoothing/differential/ integration kit, which can complete the calculation of peak height, peak area and peak potential of CV curves.
CS studio also provides powerful non-linear fitting on Butler-Volmer equation of polarization curve. It can calculate Tafel slope, corrosion current density, limitation current, polarization resistance, corrosion rate. It can also calculate the power spectrum density, noise resistance and noise spectrum resistance based on the electrochemical noise measurements.
CS Studio software can achieve real time saving of the measuring data. The data can be automatically saved even in case of sudden power off.
CS studio kit has a built-in versatile timing policy for combined measurements, which can facilitate the automation of experiments and save time.
Battery analysis: charge & discharge efficiency, capacity, specific capacitance, charge & discharge energy etc.
EIS analysis: Bode, Nyquist, Mott-Schottky plot.
CS350 Eis Electrochemical Workstation
 
 
TECHNICAL ADVANTAGES
1. Impedance (EIS)
CS350 potentiostat applies correlation integral algorithm and dual-channel over-sampling technique, and has strong anti-interference ability. It is suitable for EIS measurements of high-impedance system (>109Ω, such as coating, concrete etc.). It can also be used to obtain Mott-Schottky curve and differential capacitance curve. During test, the software can display real-time open circuit potential(OCP) without entering.
CS350 Eis Electrochemical Workstation CS350 Eis Electrochemical Workstation
EIS of AA6063 Al alloy in Ce3+ containing 3% NaCl solution        Polarization curve of Ti-based amorphous alloy &
                                                                                                       stainless steel in 3%NaCl solution
2. Polarization curve
It can complete linear polarization curve and Tafel plot measurements. The user can set the anodic reversal current (passivation film breakdown current) of the cyclic polarization curve to determine material's pitting potential and protection potential and evaluate the its susceptibility to intergranular corrosion. The software employs non-linear fitting to analyze polarization curve, and can make fast evaluation of material's anti-corrosion ability and inhibitors.
3. Voltammetry
It can do the following electroanalysis methods: Linear Sweep Voltammetry(LSV), Cyclic Voltammetry(CV), Staircase Cyclic Voltammetry(SCV), Square wave voltammetry(SWV), Differential Pulse Voltammetry(DPV), Normal Pulse Voltammetry(NPV), AC voltammetry(ACV), Stripping voltammetry etc. It integrates calculation of peak area, peak current and standard curve analysis.
CS350 Eis Electrochemical Workstation CS350 Eis Electrochemical Workstation
LSV curve: mesoporous carbon material in 0.1M KOH        CV curves of PPy supercapacitor in 0.5 mol/L H2SO4

4. Electrochemical Noise
With high-resistance follower and zero-resistance ammeter, it measures the natural potential/current fluctuations in corrosion system. It can be used to study pitting corrosion, galvanic corrosion, crevice corrosion, and stress corrosion cracking etc. Through noise spectrum, we can evaluate the inducement, growth and death of metastable pitting and crack. Based on calculation of noise resistance and pitting index, it can complete localized corrosion monitoring.
CS350 Eis Electrochemical Workstation
Electrochemical noise of low-carbon steel in 0.05mol/L Cl-+0.1mol/L NaHCO3
5. Full floating measurement
CS350 workstation uses full-floating working electrode. It can be used for autoclave electrochemical measurements, on-line corrosion monitoring of metallic components under the ground (rebar in concrete, etc.)
6. User-defined methods
CS350 workstation supports user-defined combination measurements. The user can set cyclic  timing measurements of an electrochemical method or several methods.
We are able to provide API functions and development examples, which facilitates some users' requirements for secondary development and self-defined measurements.

Specifications
Specifications
Support 2-, 3- or 4-electrode system
Potential control range: ±10V Current control range: ±2A
Potential control accuracy: 0.1%×full range±1mV Current control accuracy: 0.1%×full range
Potential resolution: 10μV (>100Hz),3μV (<10Hz) Current sensitivity:1pA
Rise time: <1μS (<10mA), <10μS (<2A) Reference electrode input impedance:1012Ω||20pF
Current range: 2nA~2A, 10 ranges Compliance voltage: ±21V
Maximum current output: 2A CV and LSV scan rate : 0.001mV~10,000V/s
CA and CC pulse width: 0.0001~65,000s Current increment during scan: 1mA@1A/ms
Potential increment during scan: 0.076mV@1V/ms SWV frequency: 0.001~100 kHz
DPV and NPV pulse width: 0.0001~1000s AD data acquisition:16bit@1 MHz,20bit@1 kHz
DA Resolution:16bit, setup time:1μs Minimum potential increment in CV: 0.075mV
IMP frequency: 10μHz~1MHz Low-pass filters: Covering 8-decade
Potential and current range: Automatic
PC and O/S requirement
 Interface: USB 2.0 Operating System: 
Windows 2000/NT/XP/ win7/win8/win10
Weight / Measurements
Net weight: 6.5kg Gross weight: 10kg
Instrument size: 36.5 x 30.5 x16cm; After package: 52.5 x 37.5x 22.5cm
Electrochemical Impedance Spectroscopy(EIS)
Signal generator
Frequency range:10μHz~1MHz AC amplitude:1mV~2500mV
DC Bias:-10~+10V Output impedance:50Ω
Waveform: sine wave, triangular wave and square wave Wave distortion:<1%
Scanning mode: logarithmic/linear, increase/decrease
Signal analyzer
Integral time:minimum:10ms or the longest time of a cycle Maximum:106 cycles or 105s
Measurement delay:0~105s
DC offset compensation
Potential automatic compensation range:-10V~+10V Current compensation range:-1A~+1A
Bandwidth: 8-decade frequency range, automatic and manual setting
 
Software
Techniques / electrochemical methods CS310 CS350
Stable polarization Open Circuit Potential (OCP)
Potentiostatic (I-T curve)
Galvanostatic
Potentiodynamic(Tafel plot)
Galvanodynamic
Transient polarization Multi-Potential Steps
Multi-Current Steps
Potential Stair-Step (VSTEP)
Galvanic Stair-Step (ISTEP)
Chrono methods Chronopotentiometry (CP)
Chronoamperometry (CA)
Chronocoulometry (CC)
Voltammetry Cyclic Voltammetry (CV)
Linear Sweep Voltammetry (LSV)
Staircase Voltammetry (SCV) #  
Square wave voltammetry (SWV) #  
Differential Pulse Voltammetry (DPV)#  
Normal Pulse Voltammetry (NPV)#  
Differential Normal Pulse Voltammetry (DNPV)#  
ACvoltammetry (ACV) #  
2nd Harmonic A.C.Voltammetry (SHACV)  
Amperometry Differential Pulse Amperometry (DPA)  
Double Differential Pulse Amperometry (DDPA)  
Triple Pulse Amperometry (TPA)  
Integrated Pulse Amperometric Detection (IPAD)  
EIS EIS vs Frequency (IMP)
EIS vs Time (IMPT)
EIS vs Potential (IMPE)(Mott-Schottky)
Corrosion test Electrochemical Potentiokinetic Reactivation(EPR)
Electrochemical Noise(EN)
Zero resistance Ammeter (ZRA)
Battery test Battery charge and discharge
Galvanostatic charge and discharge(GCD)
Extensions Data Logger
Electrochemical stripping/deposition  
Bulk electrolysis with Coulometry (BE)