Model NO.
CS2350M
Type
Measurement Type
Number of Channels
2
Max. Current Output
±2A
Potential Range
±10V
Eis Frequency
10μHz~1MHz
Applications
Rrde, Battery, Materials, Corrosion etc
Power Supply
AC 110V~240V, 50/60Hz
Weight
7kg
Transport Package
Standard Carton
Specification
36x30x16CM
Trademark
Corrtest
Origin
China
HS Code
9027899090
Production Capacity
1000 Sets/Year

Product Description

BiPotentiostat/BiGalvanostat with built-in EIS model CS2350M has two sets of built-in independent potentiostat /galvanostat. So it equals that you have 2 sets potentiostat in one instrument. Full floating module and electrical isolation design guarantee each channel is totally independent, which ensures accurate data. Each set provides full electrochemical techniques including EIS. Experiments can be conducted simultaneously in each channel. Besides this, the two channels can jointly complete experiment of two-working electrode system such as RRDE and Hydrogen diffusion. CS2350M bipotentiostat is the real double-channel potentiostat. It uses Ethernet connection. EIS module is included in both channels.


Bipotentiostat for Rrde and Rde CS2350m with Eis

Applications
(1) Electrosythesis, electrodeposition (electroplating), anodic oxidation, electrolysis
(2) Electrocatalysis such as Oxygen reduction reaction (ORR), OER, HER, CO2 reduction.
(3) Li-ion battery, solar cell, fuel cell, supercapacitor, advanced function materials, sensor, etc
(4) Corrosion behavior of metals, and anti-corrosion evaluation

(5) Fast evaluation of inhibitor, water quality stabilizer, coating, and cathodic protection efficiency.

Rotating Ring-Disk Electrode (RRDE)
Oxidation/reduction reaction (ORR) study: while measuring the polarization curve of disk electrode in the main channel, apply a constant polarization potential on the ring electrode, and thus detect the intermediate products on the disk electrode. RRDE test becomes the typical method for ORR study. CS2350M can be connected to any RRDE equipment.    
Bipotentiostat for Rrde and Rde CS2350m with Eis
Bipotentiostat for Rrde and Rde CS2350m with Eis

Hydrogen Diffusion Test (HDT)
CS2350M bipotentiostat is combined with H-cells. By measuring current of cathode hydrogen charging and hydrogen atoms anode oxidation, it can further calculate the diffusion coefficient of hydrogen atoms in metal and hydrogen flux.
Bipotentiostat for Rrde and Rde CS2350m with EisBipotentiostat for Rrde and Rde CS2350m with Eis
  
Faradaic efficiency test
In electrocatalysis, the Faradaic efficiency is measured to evaluate the performance of the catalyst. The cable connection is shown in below picture. A constant current will be applied on the disk and occur OER and produce oxygen. A constant voltage is applied on the ring and it occurs ORR and consume oxygen. The Faradaic efficiency can be calculated based on disk current and ring current.

Bipotentiostat for Rrde and Rde CS2350m with EisBipotentiostat for Rrde and Rde CS2350m with Eis

Specifications 
 
Specifications
Support 2-, 3- or 4-electrode system Interface: Ethernet
Potential control range: Primary Channel: ±10V second Channel: ±10V Current control range: ±1A in each channel
Potential control accuracy: 0.1%×full range±1mV Current control accuracy: 0.1%×full range
Potential resolution: 10μV (>100Hz), 3μV (<10Hz) Current sensitivity:1pA
Rise time: <1μS (<10mA), <10μS (<2A) Reference electrode input impedance:1012Ω||20pF
Current range: 2nA~2A, 10 ranges Compliance voltage: ±21V
Maximum current output: ±1A in each channel CV and LSV scan rate: 0.001mV~10,000V/s
CA and CC pulse width: 0.0001~65,000s Current increment during scan: 1mA@1A/ms
Potential increment during scan: 0.076mV@1V/ms SWV frequency: 0.001~100 kHz
DPV and NPV pulse width: 0.0001~1000s AD data acquisition:16bit@1 MHz,20bit@1 kHz
DA Resolution:16bit, setup time:1μs Minimum potential increment in CV: 0.075mV
IMP frequency: 10μHz~1MHz Low-pass filters: Covering 8-decade
Potential and current range: Automatic Weight / Measurements: 6.5kg,36 x 30 x16cm
 Operating System: Windows 10/11
Electrochemical Impedance Spectroscopy (EIS)
Signal generator
Frequency range:10μHz~1MHz AC amplitude:1mV~2500mV
DC Bias: -10~+10V Output impedance:50Ω
Waveform: sine wave, triangular wave and square wave Wave distortion:<1%
Scanning mode: logarithmic/linear, increase/decrease
Signal analyzer
Integral time: minimum:10ms or the longest time of a cycle Maximum:106 cycles or 105s
Measurement delay:0~105s
DC offset compensation
Potential automatic compensation range: -10V~+10V Current compensation range: -1A~+1A
Bandwidth: 8-decade frequency range, automatic and manual setting

Software -Techniques/Methods of CS235M
Stable polarization
  • Open Circuit Potential (OCP)
  • Potentiostatic (I-T curve)
  • Galvanostatic
  • Potentiodynamic (Tafel plot)
  • Galvanodynamic (DGP)
Transient Polarization
  • Multi Potential Steps
  • Multi Current Steps
  • Potential Stair-Step (VSTEP)
  • Galvanic Stair-Step (ISTEP)
Chrono Method
  • Chronopotentiometry (CP)
  • Chronoamperametry (CA)
  • Chronocaulometry (CC)
Voltammetry
  • Linear Sweep Voltammetry (LSV)
  • Cylic Voltammetry (CV)
  • Staircase Voltammetry (SCV)
  • Square Wave Voltammetry (SWV)
  • Differential Pulse Voltammetry (DPV)
  • Normal Pulse Voltammetry (NPV)#
  • Differential Normal Pulse Voltammetry (DNPV)
  • AC Voltammetry (ACV)
  • 2nd harmonic AC Voltammetry (SHACV)
  • Fourier Transform AC Voltammetry (FTACV)
Electrochemical Impedance Spectroscopy (EIS)
  • Potentiostatic EIS (Nyquist, Bode)
  • Galvanostatic EIS
  • Potentiostatic EIS (Optional freq.)
  • Galvanostatic EIS(Optional freq.)
  • Mott-Schottky
  • Potentiostatic EIS vs. Time (Single freq.)
  • Galvanostatic EIS vs. Time (Single freq.)
Corrosion Measurements
  • Cyclic polarization curve (CPP)
  • Linear polarization curve (LPR)
  • Electrochemical Potentiokinetic Reactivation (EPR)
  • Electrochemical Noise (EN)
  • Zero resistance Ammeter (ZRA)
Battery test
  • Battery Charge and Discharge
  • Galvanostatic Charge and Discharge (GCD)
  • Potentiostatic Charging and Discharging (PCD)
  • Potentiostatic Intermittent Titration Technique (PITT)
  • Galvanostatic Intermittent Titration Technique (GITT)
Bipotentiostat
  • Hydrogen Diffusion Test (HDT)
  • Rotating Ring Disk Electrode(RRDE)
  • Faradaic efficiencyTest(FE)
Amperometric
  • Differential Pulse Amperometry (DPA)
  • Double Differential Pulse Amperometry (DDPA)
  • Triple Pulse Amperometry (TPA)
  • Integrated Pulse Amperometric Detection (IPAD)
Stripping Voltammetry
  • Potentiostatic Stripping
  • Linear Stripping
  • Staircase Stripping
  • Square Wave Stripping
  • Differential Pulse Voltammetry Stripping
  • Normal Pulse Voltammetry Stripping
  • Differential Normal Pulse Voltammetry Stripping
 
 




 
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2019

Suppliers with verified business licenses

Manufacturer/Factory
Registered Capital
739010.91 USD
Plant Area
681.69 square meters