• Single Channel Potentiostat Galvanostat for Corrosion Measurement
  • Single Channel Potentiostat Galvanostat for Corrosion Measurement

Single Channel Potentiostat Galvanostat for Corrosion Measurement

After-sales Service: Free
Warranty: 5 Years
Customized: Customized
Structure: Desktop
Certification: CE, ISO
Application: School, Hospital, Lab
Gold Member Since 2019

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
CS350/CS310/CS300/CS150 Single channel models
Type
Measurement Type
Manufacturer
Wuhan Corrtest Instruments Corp., Ltd.
Weight
6.5kg
Max. Current Output
±2A
Potential Range
±10V
Eis Frequency
10μHz~1MHz
Applications
Battery, Materials, Corrosion etc
Power Supply
AC 110V~240V, 50/60Hz
Transport Package
Carton
Specification
36x30x16CM
Trademark
Corrtest
Origin
China
HS Code
9027899090
Production Capacity
1000 Sets/Year

Product Description

CS electrochemical workstation (potentiostat / galvanostat) contains a fast digital function generator, high-speed data acquisition circuitry, a potentiostat and a galvanostat. With high performance in stability and accuracy with advanced hardware and well-functioned software, it is a comprehensive research platform for corrosion, batteries, electrochemical analysis, sensor, life science and environmental chemistry etc.

Single Channel Potentiostat Galvanostat for Corrosion Measurement
 

Applications        
       
(1) Reaction mechanism of Electrosynthesis, electrodeposition (electroplating), anodic oxidation, etc.
(2) Electrochemical analysis and sensor;  
(3) New energy materials (Li-ion battery, solar cell, fuel cell, supercapacitors), advanced functional materials, photoelectronic materials;
(4)Corrosion study of metals in water, concrete and soil etc;
(5) Fast evaluation of corrosion inhibitor, water stabilizer, coating and cathodic protection efficiency.



Specifications
Specifications
Support 2-, 3- or 4-electrode system Potential and current range: Automatic
Potential control range: ±10V Current control range: ±2A
Potential control accuracy: 0.1%×full range±1mV Current control accuracy: 0.1%×full range
Potential resolution: 10μV (>100Hz),3μV (<10Hz) Current sensitivity:1pA
Rise time: <1μS (<10mA), <10μS (<2A) Reference electrode input impedance:1012Ω||20pF
Current range: 2nA~2A, 10 ranges Compliance voltage: ±21V
Maximum current output: 2A CV and LSV scan rate: 0.001mV~10,000V/s
CA and CC pulse width: 0.0001~65,000s Current increment during scan: 1mA@1A/ms
Potential increment during scan: 0.076mV@1V/ms SWV frequency: 0.001~100 kHz
DPV and NPV pulse width: 0.0001~1000s AD data acquisition:16bit@1 MHz,20bit@1 kHz
DA Resolution:16bit, setup time:1μs Minimum potential increment in CV: 0.075mV
IMP frequency: 10μHz~1MHz Low-pass filters: covering 8-decade
Operating System: Windows 2000/NT/XP/7/8/10  Interface: USB 2.0
Weight / Measurements: 6.5kg, 36.5 x 30.5 x16 cm
EIS (Electrochemical Impedance Spectroscopy)
Signal generator
Frequency range:10μHz~1MHz AC amplitude:1mV~2500mV
DC Bias: -10~+10V Output impedance: 50Ω
Waveform: sine wave, triangular wave and square wave Wave distortion: <1%
Scanning mode: logarithmic/linear, increase/decrease
Signal analyzer
Integral time: minimum:10ms or the longest time of a cycle Maximum:106 cycles or 105s
Measurement delay: 0~105s
DC offset compensation
Potential automatic compensation range: -10V~+10V Current compensation range: -1A~+1A
Bandwidth: 8-decade frequency range, automatic and manual setting



Electrochemical methods/Techniques (Models' comparison)
Guidance:
Hardware specs and appearance are the same for various models, difference is in software part.

Model CS350 (with built-in EIS) is the most comprehensive model, includes all methods incl. EIS. It's suitable for various applications, and also for teaching

Model CS310 (with built-in EIS) also includes EIS module. But it has less voltammetry methods compared with CS350. CS310 is a cost-effective model if you need EIS. It's an ideal model for corrosion, battery studies etc.

Model CS150 (w/o EIS) is the basic model incl. basic methods such as CV, LSV, charge and discharge, Tafel plot, etc

 
Techniques CS150 CS300 CS310 CS350
Stable
polarization
Open Circuit Potential (OCP)
Potentiostatic (I-T curve)
Galvanostatic
Potentiodynamic(Tafel plot)
Galvanodynamic
Transient polarization Multi-Potential Steps
Multi-Current Steps
Potential Stair-Step (VSTEP)
Galvanic Stair-Step (ISTEP)
Chrono
methods
Chronopotentiometry (CP)  
Chronoamperometry (CA)  
Chronocoulometry (CC)  
Voltammetry Cyclic Voltammetry (CV)
Linear Sweep Voltammetry (LSV)(I-V)
Staircase Voltammetry (SCV) #    
Square wave voltammetry (SWV) #    
Differential Pulse Voltammetry (DPV)#    
Normal Pulse Voltammetry (NPV)#    
Differential Normal Pulse Voltammetry (DNPV)#    
AC voltammetry (ACV) #    
2nd Harmonic A.C.Voltammetry (SHACV)    
Amperometry Differential Pulse Amperometry (DPA)      
Double Differential Pulse Amperometry (DDPA)      
Triple Pulse Amperometry (TPA)      
Integrated Pulse Amperometric Detection (IPAD)      
EIS EIS vs Frequency (IMP)    
EIS vs Time (IMPT)    
EIS vs Potential (IMPE)(Mott-Schottky)    
Corrosion
 test
Cyclic polarization curve (CPP)
Linear polarization curve (LPR)
Electrochemical Potentiokinetic Reactivation (EPR)
Electrochemical Noise(EN)
Zero resistance Ammeter (ZRA)
Battery test Battery charge and discharge
Galvanostatic charge and discharge(GCD)
Potentiostatic Charging and Discharging(PCD)
Potentiostatic Intermittent Titration Technique(PITT)
Galvanostatic Intermittent Titration Technique(GITT)
Extensions Data Logger
Bulk electrolysis with Coulometry (BE)

Standard supply list for each set

Instrument host x1
CS studio software x1
Power cable x1
USB cable x1
Cell cable x2
Dummy cell(1kΩ||100µF) x1
Manual x1
Warranty cardx1


Service

1. Warranty period: 5 years
2. Provide installation guide, manual, software installation video, and training videos.
3. Provide repair service for FREE
4. Lifetime free software upgrading and technical service


 
SOFTWARE FEATURES
CS studio software provides users a versatile smoothing/differential/ integration kit, which can complete the calculation of peak height, peak area and peak potential of CV curves.

Single Channel Potentiostat Galvanostat for Corrosion Measurement
CS studio also provides powerful non-linear fitting on Butler-Volmer equation of polarization curve. It can calculate Tafel slope, corrosion current density, limitation current, polarization resistance, corrosion rate. It can also calculate the power spectrum density, noise resistance and noise spectrum resistance based on the electrochemical noise measurements.
Single Channel Potentiostat Galvanostat for Corrosion Measurement
CS Studio software can achieve real time saving of the measuring data. The data can be automatically saved even in case of sudden power off.
CS studio kit has a built-in versatile timing policy for combined measurements, which can facilitate the automation of experiments and save time.
Battery analysis: charge & discharge efficiency, capacity, specific capacitance, charge & discharge energy etc.


EIS analysis: Bode, Nyquist, Mott-Schottky plot  

 
 
Single Channel Potentiostat Galvanostat for Corrosion Measurement


TECHNICAL ADVANTAGES
1. Impedance (EIS)
CS potentiostat applies correlation integral algorithm and dual-channel over-sampling technique, and has strong anti-interference ability. It is suitable for EIS measurements of high-impedance system (>109Ω, such as coating, concrete etc.). It can also be used to obtain Mott-Schottky curve and differential capacitance curve. During test, the software can display real-time open circuit potential(OCP) without entering.
Single Channel Potentiostat Galvanostat for Corrosion Measurement
EIS of AA6063 Al alloy in Ce3+ containing 3% NaCl solution         
2. Polarization curve
It can complete linear polarization curve and Tafel plot measurements. The user can set the anodic reversal current (passivation film breakdown current) of the cyclic polarization curve to determine material's pitting potential and protection potential and evaluate the its susceptibility to intergranular corrosion. The software employs non-linear fitting to analyze polarization curve, and can make fast evaluation of material's anti-corrosion ability and inhibitors.
Single Channel Potentiostat Galvanostat for Corrosion Measurement
                                                                    Polarization curve of Ti-based amorphous alloy & stainless steel in 3%NaCl solution

3. Voltammetry
It can do the following electroanalysis methods: Linear Sweep Voltammetry(LSV), Cyclic Voltammetry(CV), Staircase Cyclic Voltammetry(SCV), Square wave voltammetry(SWV), Differential Pulse Voltammetry(DPV), Normal Pulse Voltammetry(NPV), AC voltammetry(ACV), Stripping voltammetry etc. It integrates calculation of peak area, peak current and standard curve analysis.
Single Channel Potentiostat Galvanostat for Corrosion MeasurementSingle Channel Potentiostat Galvanostat for Corrosion Measurement
      
Up: LSV curve: mesoporous carbon material in 0.1M KOH
Down: CV curves of PPy supercapacitor in 0.5 mol/L H2SO4     

4. Electrochemical Noise
With high-resistance follower and zero-resistance ammeter, it measures the natural potential/currentfluctuations in corrosion system. It can be used to study pitting corrosion, galvanic corrosion, crevice corrosion, and stress corrosion cracking etc. Through noise spectrum, we can evaluate the inducement, growth and death of metastable pitting and crack. Based on calculation of noise resistance and pitting index, it can complete localized corrosion monitoring.
Single Channel Potentiostat Galvanostat for Corrosion Measurement
Electrochemical noise of low-carbon steel in 0.05mol/L Cl-+0.1mol/L NaHCO3

5. Full floating measurement
CS workstation uses full-floating working electrode. It can be used for autoclave electrochemical measurements, on-line corrosion monitoring of metallic components under the ground (rebar in concrete, etc.)

6. User-defined methods
CS workstation supports user-defined combination measurements. The user can set cyclic  timing measurements of an electrochemical method or several methods.
  We are able to provide API functions and development examples, which facilitates some users' requirements for secondary development and self-defined measurements.




Some of the published papers

Single Channel Potentiostat Galvanostat for Corrosion Measurement
Single Channel Potentiostat Galvanostat for Corrosion Measurement



 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2019

Suppliers with verified business licenses

Manufacturer/Factory
Registered Capital
739010.91 USD
Plant Area
681.69 square meters